In many places from chemistry laboratories to industrial services, in order to ensure the security of life and property against a attainable fireplace hazard, extinguishing methods are used along with detection and alarm techniques. It is also extremely essential that the extinguishing methods installed can be triggered by the fireplace extinguishing management panel, so as to eliminate a possible hearth with early intervention.
In order to satisfy these needs, and with 35 years of sectoral information and experience, Mavili Elektronik offers:
Maxlogic Conventional Fire Extinguishing Control Panel operating based on the cross-zone detection precept;
Maxlogic Extinguishing Status Indicator Unit, which allows the remote performance of the indications and controls on the Control Panel;
Maxlogic Extinguishing Output Expansion Panel;
Maxlogic Extinguishant Manual Release Button, which allows the extinguishing process to be began manually and remotely; and
to ensure that the extinguishing course of may be paused, Maxlogic has produced the Extinguishant Emergency Stop Button.
All these units are produced utilizing surface-mount expertise and are aimed toward making the automation of the extinguishing system and fireplace and fuel detection system good.
Image copyright: Mavili
Mavili Elektronik develops its merchandise by always considering the wants of the installation. In circumstances that require the mixing of the extinguishing system with the clever addressable hearth detection system, it supplies solutions by way of the monitoring modules that also have a ‘supervised’ choice.
Supervised monitoring modules play an important function in controlling the continuity of the cable connection between the loop and the extinguishing system. Failure to detect a attainable open or brief circuit within the wiring between the contact monitoring modules and the peripheral systems could cause disruption of the triggering, with potentially critical penalties. For this reason, when choosing monitoring modules, it must be taken into consideration that they have supervised options.
Image copyright: Mavili
Since Maxlogic clever addressable fire detection and alarm control panels are continually communicating with ‘supervise’ contact monitoring modules linked to cable loops and compliant with EN 54-17 and EN 54-18 requirements, it makes it easier to watch conditions such as open circuits and short circuits which will happen in the system. Many duties can be carried out in the fireplace extinguishing installation, such because the control and monitoring of all valves that may interrupt the flow of water, water move alarm switches, pressure switch, and electrical or diesel hearth pumps.
By adding เกจ์ลมsumo monitoring modules to 2 separate relay outputs situated above the Maxlogic Conventional Fire Extinguishing Control Panel, one of many modules can be used to control errors and the opposite to control the fire scenario, monitoring and control of the extinguishing system through an clever addressable fire detection and alarm system could be performed successfully.
For more data, go to www.mavili.com.tr/en
Share