Gas: On-site calibration optimised at the metering skid

On-site calibration of measuring instruments is frequently very time-consuming and expensive. เพรสเชอร์เกจ is also true for applications with several measurands. One example of this may be the metering skid, a system for the custody transfer measurement of the amount of natural gas transferred. A global player in the industry from Saudi Arabia has significantly streamlined the testing process at this point: with the multi-functional CPH8000-P1 calibrator from WIKA, a ?calibration laboratory in a case?.
The heart of a metering skid may be the flow computer. It processes the information from all the measuring instruments and calculates the precise amount of natural gas that flows to the client. Natural gas is compressible, so the tabs on pressure and temperature during gas transfer plays an essential role.
Verification may be the law
Because even small measuring errors could cause noticeable losses in turnover, the measuring instruments should be calibrated regularly. Normally, this is done at the facility. Each on-site calibration must also be verified relative to regulations. This implies proving consistent repeatability of the test outcomes and traceability to the assigned references. In addition, the regulations require the test equipment to be approved for use in hazardous areas.
In view of the requirements, the calibration personnel of WIKA customers previously had to utilize many different devices so as to adequately fulfil their tasks. Besides pressure and temperature calibrators, this included a pneumatic pump for the test pressure, a HART� communicator and a resistance decoder. The on-site calibration cost effort and time accordingly.
เกจวัดแรงดัน -P1 multi-functional calibrator significantly reduces the effort necessary for on-site calibration.
Four measuring channels
The gas company in Saudi Arabia has reduced this effort in one fell swoop with the CPH8000-P1 portable multi-function calibrator from WIKA. The case-mounted instrument calibrates pressure measuring instruments together with resistance thermometers and thermocouples. The test pressure is generated having an integrated pump. The CPH8000-P1 has four measuring channels. It can thus perform and display around four measurements simultaneously. The ATEX-approved version also supplies the test items and reference sensors in the metering skid with voltage (DC 24 V) without danger.
Documentation without problems
During the test procedure, the CPH8000-P1 ? via its integrated HART� module ? communicates directly with the measuring instruments, which may also be HART�-capable. Its powerful data logger and the large memory capacity support an individual in the next documentation of the on-site calibration. The machine provides all the details relevant for verification.
Note
Detailed home elevators the model CPH8000 multi-function calibrators can be acquired on the WIKA website. Each instrument has a modular design and can therefore be specified for the respective range of applications. In case you have any more questions, your contact will gladly help you.

Scroll to Top