Tyco Fire Protection Products showcased its experience in water mist suppression options at the International Water Mist Association (IWMA) Conference in Istanbul. Dr Tim Nichols, Sales Director Water Mist EMEA, gave a presentation entitled ‘Fire Protection of Compact Archive Storage utilizing Water Mist’, where he mentioned how the extinguishant is nicely suited to the safety of irreplaceable works and artefacts in extremely priceless buildings.
Tim’s lecture centered on a hearth check protocol that was formulated to confirm the performance and use of Tyco’s own water mist solution, AquaMist, in an historic building, house to precious archive storage. The National Fire Protection Association (NFPA) 750 standard requires that, when using a water mist suppression system, fire testing is undertaken pertinent to the danger. However, of the printed fireplace test protocols listed in NFPA 750, none details the requirements for archives that comprise roller (compact) racking. Many of the racks in the focused building are of the ‘roller’ kind, which restrict the quantity of house for constructing services, including those for extinguishing system pipework.
Together with the project stakeholders, Tyco devised the protocol to include check rig and format, test sort, fire load, information acquisition (for example, sensors and imaging), hardware required (such as pumps, nozzles, pipe, tank, generator), and well being and security procedures (for instance, the hearth brigade). The associated efficiency based mostly fire exams have been then designed to copy the range of utility parameters associated with archive storage.
While ignition sources on the unique web site had been recognized to be minimal, and the primary fire supply confirmed as arson, the multi-level building poses numerous challenges that had to be considered when formulating the hearth test protocol to ensure efficient protection. Low ceilings and quite a few obstructions, such as lighting, ducts and pillars, contribute towards the confined setting of the archive storage basement stage. Items are saved in a mixture of open racks and compact racks, which supply less than a 150mm hole between themselves and the ceiling, and there might be restricted on-site water storage. Pre- ไดอะแฟรม restricted entry and exits beneath and above floor, so it’s essential for storage space to be maximised and safe egress supplied in case of the occasion of a fireplace. In addition, the extremely valuable nature of the storage contents meant that the chosen fireplace suppression resolution had to ensure minimal harm to those historical gadgets.
To achieve validation, the checks had to meet varied objectives. These comprised rapid control of the fire inside a prescribed area (in this case, defined as within a block of racks); control of temperature; attenuation of radiation; and minimisation of collateral injury by way of water clean-up. They also had to take into account varied parameters, together with the specified excessive stress mist system; a 30 minute run time; and an annual measurable achievement goal (AMAO) outlined based on a formulation based on the quantity of nozzles activating throughout testing.
The hearth exams, carried out for each open and curler racks with minimum storage gaps, have been undertaken in a personalized check rig, designed, built and fitted to replicate the precise specification, racking arrangements and storage supplies of the site. Considered a high load, the fuel materials had been similar to that found in archive storage, including paper, books, micro-film and CD instances.
Success was defined by cross or fail criteria and decided by detailed quantitative measurements on system configuration, hydraulic evaluation, discharge stress, discharge sequence, hearth unfold, temperature, fireplace injury and water consumption. In each checks, Tyco’s AquaMist system operated effectively and was observed to suppress and management the fireplace effectively. The project group was impressed by the shortage of fireplace and smoke harm to the supplies and structure and the product has since been installed in the building in query.
“The IWMA conference is a incredible alternative to focus on the advantages of water mist as a fireplace suppression resolution, in addition to reveal its versatility in a broad range of purposes,” comments Dr Tim Nichols. “Identifying a spot out there and taking the chance to formulate a hearth test protocol for archive storage enabled us to validate the professional capabilities of our AquaMist system and facilitate safety of a customer’s extremely priceless property.”

For more info, go to www.tfppemea.com