Fire Safety for Very Tall Buildings

Very tall buildings have unique fireplace security design issues that are not experienced in different kinds of buildings. For instance, as a result of the height of the structure is past the attain of ladders, tall buildings are equipped with more fireplace safety features as it’s not attainable for the hearth department to initiate exterior rescues from ladders and suppress fires with exterior hose streams.
In regards to fireside security, the efficiency history of very tall buildings while very profitable, has not been with out catastrophic incidents. Many of those incidents have resulted in 1) numerous deaths and accidents, 2) excessive property loss and 3) disruptions in enterprise continuity. For example, the One Meridian Plaza high-rise hearth in Philadelphia that occurred in 1991 resulted in the lack of three firefighters and constructing never being re-opened. In 1988, the fireplace within the Interstate Bank Building in Los Angeles skilled one fatality and resulted in the constructing being out of use for six months.
Based on analysis and lessons realized, the model constructing codes have made significant progress in addressing hearth safety issues in very tall buildings. At the identical time, the complexity and distinctive challenges of today’s very tall buildings have created an setting where complete performance-based options have turn into a necessity.
To help the design community with growing performance-based fireplace safety solutions for very tall buildings, in 2013, the Society of Fire Protection Engineers (SFPE) partnered with the International Code Council (ICC) to develop the Engineering Guide: Fire Safety in Very Tall Buildings.1 This publication is written as a information to be used in conjunction with native codes and standards and serves as an added tool to those concerned within the fireplace protection design of distinctive tall buildings. The information focuses on design points that affect the fireplace security performance of tall buildings and how engineers can incorporate performance-based fireplace protection through hazard and risk analysis methodologies into the design of tall buildings. This article will focus on some of the distinctive fire safety design strategies/methodologies employed in the design of tall buildings which are referenced in the ICC/SFPE Guide.
Emergency Egress
Developing an effective evacuation strategy for a tall constructing is challenging because the time to finish a full constructing evacuation increases with building height. At the same time, above certain heights, the traditional methodology of requiring all occupants to simultaneous evacuate is in all probability not practical as occupants turn out to be extra susceptible to extra risks when evacuating by way of stairways. That is why tall buildings often employ non-traditional or alternative evacuation methods.
When designing an egress plan for a tall building, the first goal must be to supply an appropriate means to allow occupants to maneuver to a place of safety. To accomplish this aim, there are several evacuation methodologies which are out there to the design team. These evacuation methods can include but usually are not restricted to 1) defend-in-place, 2) moving people to areas of refuge and 3) phased/progressive evacuation. It is also attainable that a mixture of those methods may be this finest answer. When deciding on an appropriate strategy, the design group ought to think about the required degree of security for the building occupants and the building efficiency goals which might be identified by the building’s stakeholders.
Using protected elevators has turn out to be another evacuation technique that is changing into extra prevalent in the design of tall buildings. In addition to aiding the hearth department with operations and rescues, protected elevators are now being used for building evacuation, significantly for occupants with disabilities. When contemplating elevators in an evacuation strategy, there are a variety of design considerations to think about: 1) safety and reliability of the elevators, 2) coordination of elevator controls and constructing safety techniques, 3) training of constructing occupants and first responders and 4) communication to constructing occupants through the emergency.
Tall buildings often employ non-traditional or alternative evacuation strategies.
Fire Resistance
The consequences of partial or global collapse of tall buildings due to a severe fireplace pose a major risk to a giant number of individuals, the fire service and surrounding buildings. At the identical time, tall buildings often have unique design options whose position in the construction and fire response are not easily understood utilizing conventional hearth safety methods. These unique factors could warrant a have to undertake a sophisticated structural fire engineering evaluation to show that the building’s performance aims are met.
Performance-based design of structural fireplace resistance entails three steps: (1) determination of the thermal boundary conditions to a construction ensuing from a hearth; (2) calculation of the thermal response of the structure to the fireplace publicity, and (3) dedication of the structural response of the structure. Guidance on performing this sort of analysis can be found in the SFPE Engineering Standard on Calculating Fire Exposures to Structures2, and SFPE Engineering Standard on Calculation Methods to Predict the Thermal Performance of Structural and Fire Resistive Assemblies.3
Water-Based Fire Suppression Systems
In tall buildings, the water provide required for fireplace protection techniques could be larger than the capability of the public water provide. As such, hearth protection system water provides for sprinkler techniques and standpipes require the use of pumps and/or gravity water tanks to boost the water strain. Reliability of this water supply is a key consideration. As such, redundant fireplace pumps, gravity-based storage supplies, or both could additionally be needed to reinforce system reliability.
Another problem to assume about when designing water-based hearth suppression techniques is stress control as it’s possible for system components to be uncovered to pressures that exceed its most working stress. Consequently, it could be necessary to design vertical pressure zones to control pressures in the zone. Additionally, strain regulating valves are often needed. When installed, care should be taken to ensure that these stress regulating valves are put in correctly and adequately maintained.
Fire Alarm and Communication Systems
Providing constructing occupants with accurate data during emergencies will increase their capacity to make appropriate decisions about their own safety. weksler pressure gauge ราคา and communication systems are an important supply of this information. Very tall buildings make use of voice communication methods that are built-in into the fireplace alarm system. When designing voice communication methods it could be very important be certain that the system offers dependable and credible data.
Fire alarm system survivability is another import factor to suppose about in hearth alarm system design. For tall buildings, consideration ought to be given in order that an assault by a fireplace in an evacuation zone does not impair the voice messaging outdoors the zone. Some of the design issues to achieve survivability might include: 1) safety of management tools from hearth, 2) protection of circuits. 3) configuration of circuits and 4) shielding of panels.
Tall buildings usually employ smoke management methods that both vent, exhaust or limit the spread of smoke.
Smoke Control
Controlling the spread of smoke is extra sophisticated in tall buildings. For example, tall buildings expertise a phenomenon referred to as stack effect. Stack effect happens when a tall constructing experiences a stress difference throughout its height on account of temperature differentials between the skin air temperature and the inside constructing temperature. This causes air to move vertically, relying on the skin air temperature – both upward or downward in a constructing. It can also trigger smoke from a constructing fire to unfold all through the building if not controlled. That is why tall buildings often make use of smoke management systems that either vent, exhaust or restrict the spread of smoke.
Other concerns in tall buildings included the air motion created by the piston effect of elevators and the consequences of wind. Air motion caused by elevator automobiles ascending and descending in a shaft and the consequences of wind can lead to smoke motion in tall buildings. These impacts turn into more pronounced as the peak of the constructing increase.
Because very tall buildings complicate smoke unfold, efficient smoke control is tougher to attain. The potential solutions are quite a few and include a mixture of energetic and passive features corresponding to but not limited to: 1) smoke barrier walls and flooring, 2) stairway pressurization systems, 3) pressurized zoned smoke control offered by the air-handling gear, and 4) smoke dampers. The solution carried out into the design wants to handle the building itself, its makes use of, relevant occupant traits and reliability.
First Service Issues
It goes with out saying that tall buildings present unique challenges to the hearth service. During the planning and design phases, it is necessary for the design group to work with the hearth service to debate the type of assets which are needed for an incident and the actions that shall be wanted to mitigate an incident. This contains developing construction and post-construction preplans. These preplans should embrace and never be restricted to making provisions for 1) fire service access including transport to the highest degree of the constructing, 2) establishing a water supply, 3) standpipe systems (temporary and permanent), 4) communication systems, and 5) understanding the operations of the hearth protection systems in the constructing.
One of the challenges the fireplace service faces during incidents in tall buildings is the power of firefighters to move tools to the incident location. Designers should take into account how the fireplace service can transport its tools from the response degree to the highest stage in a protected manner.
Additionally, care must be taken when designing the fire command heart as it’s going to provide the fireplace service command staff with important details about the incident. The hearth command heart needs to be accessible and will embrace 1) controls for building techniques, 2) contact information for constructing administration, 3) present buildings plans, 4) emergency response and egress plans and 5) preplans.
1 International Code Council/SFPE. (2013). Engineering Guide: Fire Safety for Very Tall Buildings. Country Club Hills, IL.
2 SFPE. (2011). SFPE Standard S.01 2011, Engineering Standards on Calculating Fire Exposures to Structures. Gaithersburg, Maryland.
3 SFPE. 2015). SFPE Standard S.02 2015, SFPE Engineering Standard on Calculation Methods to Predict the Thermal Performance of Structural and Fire Resistive Assemblies. Gaithersburg, Maryland.
Share

Scroll to Top